Hankison HIT Refrigerated Air Dryers
|
HIT Series High Inlet Temperature Refrigerated Compressed Air Dryers
This complete air treatment system replaces four separate components; the aftercooler separator dryer and filter with one compact package. The HIT Series dryers are ideal for auto body shops, auto service centers, commercial and industrial facilities currently utilizing 5 to 30 HP compressors. Guaranteed to cool, dry and clean your compressed air Hankison's HIT Series dryers are the smart choice.
Designed for Durability And Reliability:
- Easy to Select
- Easy to Install
|
- Easy to Operate
- Easy to Maintain
|
|
Capacity for Flows Based on 180°F, 82°C Inlet |
Model |
Price |
Flow Capacity scfm1 @175 psig (12 kg/cm2) |
Recommended Air Compressor Size hp |
Flow Capacity scfm1 @ 150 psig (11 kg/cm2) |
Recommended Air Compressor Size hp |
Flow Capacity scfm1 @ 125 psig (9 kg/cm2) |
Recommended Air Compressor Size hp |
Flow Capacity scfm1 @ 100 psig (7 kg/cm2) |
Recommended Air Compressor Size hp |
|
|
60Hz |
50Hz |
60Hz |
50Hz |
60Hz |
50Hz |
60Hz |
50Hz |
60Hz |
50Hz |
60Hz |
50Hz |
60Hz |
50Hz |
60Hz |
50Hz |
HIT20 |
$1,377.00 |
23 |
20 |
5 |
5 |
22 |
18 |
5 |
5 |
20 |
17 |
5 |
5 |
18 |
15 |
5 |
5 |
HIT25 |
$1,605.00 |
29 |
24 |
7.5 |
7.5 |
27 |
23 |
7.5 |
7.5 |
25 |
21 |
7.5 |
5 |
23 |
19 |
5 |
5 |
HIT35 |
$1,952.00 |
41 |
31 |
10 |
7.5 |
38 |
29 |
10 |
7.5 |
35 |
27 |
10 |
7.5 |
32 |
24 |
7.5 |
7.5 |
HIT50 |
$2,530.00 |
58 |
58 |
15 |
15 |
54 |
54 |
15 |
15 |
50 |
50 |
15 |
10 |
45 |
45 |
10 |
10 |
HIT75 |
$2,992.00 |
87 |
71 |
20 |
20 |
81 |
66 |
20 |
15 |
75 |
61 |
20 |
15 |
68 |
5 |
15 |
15 |
HIT100 |
$3,570.00 |
116 |
97 |
25 |
25 |
108 |
90 |
25 |
20 |
100 |
83 |
25 |
20 |
91 |
76 |
20 |
15 |
HIT125 |
$4,495.00 |
145 |
121 |
30 |
30 |
135 |
112 |
30 |
30 |
125 |
104 |
30 |
25 |
114 |
95 |
25 |
20 |
For typical applications where an aftercooler is installed upstream 1. Capacity@ WOoF (38°C) inlet temperature. WOoF (38°C) inlet pressure dew point, WOoF (38°C) ambient temperature, 50°F (10°C) outlet pressure dew point, and less than W psig (0.7 kg/em') pressure drop.
HIT Series Product Specifications |
Model |
Power Requirements |
Maximum Working Pressure |
Maximum Inlet Temperature |
Ambient Temperature Range |
In /Out Connections |
Dimensions |
Weight |
|
115V/1ph/ 60Hz |
220-240V/ 1ph/50Hz |
|
H |
W |
D |
|
|
|
kW |
kW |
NPT or BSP |
in |
mm |
in |
mm |
in |
mm |
lbs |
kg |
HIT20 |
0.73 |
0.60 |
250 psig 17.6 kg/cm2 |
180°F 82°C |
|
1/2" |
28 |
718 |
10 |
257 |
13 |
327 |
79 |
36 |
HIT25 |
0.73 |
0.60 |
1/2" |
28 |
718 |
10 |
257 |
13 |
327 |
80 |
36 |
HIT35 |
0.73 |
0.60 |
1/2" |
28 |
718 |
10 |
257 |
13 |
327 |
81 |
37 |
HIT50 |
1.37 |
1.08 |
3/4" |
37 |
933 |
17 |
429 |
17 |
429 |
150 |
68 |
HIT75 |
1.37 |
1.08 |
3/4" |
37 |
933 |
17 |
429 |
17 |
429 |
155 |
70 |
HIT100 |
- |
2.11 |
3/4" |
46 |
1162 |
17 |
429 |
17 |
429 |
170 |
77 |
HIT125 |
- |
2.11 |
3/4" |
46 |
1162 |
17 |
429 |
17 |
429 |
175 |
80 |